Home Latest Log In

TTC-6P-3-HF-F-M-12DC-PT-I - Surge protection device


  • Date:2024-05-22T03:14:23Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:111505421481214903851135@16qq9.1013co9m

     Business License verifiedEmail verified

     

    TTC-6P-3-HF-F-M-12DC-PT-I - Surge protection device

    2906796

    Surge protection, consisting of protective plug and base element, with integrated status indicator and knife disconnection for three signal wires with common reference potential. For HF applications and telecommunications interfaces without supply voltage. Indirect grounding via gas discharge tube, EX e approval for zone 2. Can be used in safety-related circuits up to SIL 3.


    Product type Surge protection for information technology
    Product family TERMITRAB complete
    IEC test classification C1
    C2
    C3
    D1
    Type DIN rail module, two-section, divisible
    Insulation characteristics
    Overvoltage category III
    Pollution degree 2

    Nominal voltage UN 12 V DC

    Connection method Push-in connection
    Conductor cross section flexible 0.2 mm² ... 2.5 mm²
    Conductor cross section rigid 0.2 mm² ... 4 mm²
    Conductor cross section AWG 24 ... 12

    Maximum input current 600 mA (T4 / ≤ 30 °C)
    500 mA (T4 / > 30 °C ... ≤ 50 °C)
    400 mA (T4 / > 50 °C ... ≤ 70 °C)
    Maximum input voltage 15 V DC
    Altitude ≤ 2000 m (amsl)
    Ambient temperature (operation) -40 °C ... 70 °C (T4)

    Dimensional drawing
    Width 6.2 mm +0.1 mm
    Height 105.8 mm
    Depth 100 mm (incl. DIN rail 7.5 mm)

    Color (Base element) gray (RAL 7042)
    Color (Male connector) light grey (RAL 7035)
    Flammability rating according to UL 94 V-0
    Insulating material PBT
    Housing material PBT

    Mechanical data
    Open side panel No

    Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
    Maximum continuous voltage UC 15 V DC
    10 V AC
    Rated current 600 mA (56 °C)
    Operating effective current IC at UC ≤ 100 µA
    Residual current IPE ≤ 1 µA
    Nominal discharge current In (8/20) µs (line-line) 5 kA
    Nominal discharge current In (8/20) µs (line-ground) 5 kA
    Nominal discharge current In (8/20) µs (line-signal ground) 5 kA
    Pulse discharge current Iimp (10/350) µs (line-line) 0.5 kA
    Pulse discharge current Iimp (10/350) µs (line-earth) 0.5 kA
    Pulse discharge current Iimp (10/350) µs (line-signalground) 0.5 kA
    Total discharge current Itotal (8/20) µs 10 kA
    Voltage protection level Up (line-line) ≤ 145 V (C1 - 1 kV / 500 A)
    ≤ 260 V (C2 - 10 kV / 5 kA)
    ≤ 25 V (C3 - 25 A)
    ≤ 30 V (C3 - 100 A)
    Voltage protection level Up (line-earth) ≤ 750 V (C1 - 1 kV / 500 A)
    ≤ 750 V (C2 - 10 kV / 5 kA)
    ≤ 1.1 kV (C3 - 25 A)
    ≤ 1.2 kV (C3 - 100 A)
    Voltage protection level Up (line-signalground) ≤ 80 V (C1 - 1 kV / 500 A)
    ≤ 95 V (C2 - 10 kV / 5 kA)
    ≤ 25 V (C3 - 25 A)
    ≤ 30 V (C3 - 100 A)
    Voltage protection level Up static (line-line) ≤ 40 V (C1 - 1 kV / 500 A)
    ≤ 95 V (C2 - 10 kV / 5 kA)
    Voltage protection level Up static (line-earth) ≤ 750 V (C1 - 1 kV / 500 A)
    ≤ 750 V (C2 - 10 kV / 5 kA)
    Voltage protection level Up static (line-signalground) ≤ 40 V (C1 - 1 kV / 500 A)
    ≤ 95 V (C2 - 10 kV / 5 kA)

    TTC-6P-3-HF-F-M-12DC-PT-I - Surge protection device

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.