CB TM1 1A M1 P - Thermomagnetic device circuit breaker


  • Date:2024-05-22T03:11:41Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:121935474448410911108555610@q05q.31co3m

     Business License verifiedEmail verified

     

    CB TM1 1A M1 P - Thermomagnetic device circuit breaker

    2800847

    Thermomagnetic device circuit breaker, 1-pos., tripping characteristic M1 (medium-blow), 1 changeover contact, plug for base element.


    General When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.

    Product type Thermomagnetic device circuit breakers
    Product family CB TM
    Type Male
    Number of positions 1
    No. of channels 1
    Insulation characteristics
    Degree of pollution 2

    Fuse type Automatic device
    General
    Rated voltage 50 V DC (IEC 60934)
    50 V DC (UL 1077)
    50 V DC (UL 508 - with plug-in base)
    240 V AC (Ue according to IEC 60934)
    277 V AC (UL 1077)
    277 V AC (UL 508 - with plug-in base)
    Rated insulation voltage Ui 277 V AC (UL 1077)
    250 V AC (IEC 60934)
    Rated current IN 1 A (IEC 60934)
    1 A AC (inductive load according to UL 1077)
    1 A DC (low-induction load according to UL 1077)
    1 A AC (inductive load according to UL 508 - with plug-in base)
    1 A DC (low-induction load according to UL 508 - with plug-in base)
    Rated surge voltage 2.5 kV (Increased insulation in actuation area)
    Insulation resistance Riso > 100 MΩ (500 V DC)
    Auxiliary circuit 277 V AC / 0.5 A (Low-induction)
    277 V AC / 1 A (Low-induction, maximum of 2000 cycles)
    50 V DC / 1 A (Low-induction)
    Type of actuation S type
    Tripping method TM (thermomagnetic)
    Tripping level Trip-free mechanism (positive)
    Device resistance 1100 mΩ
    Required backup fuse 15 A (I > Icn)
    Rated short-circuit switching capacity Icn 300 A (240 V AC)
    600 A (50 V DC)
    Short-circuit switching capacity 1000 A AC (277 V AC)
    1000 A DC (50 V DC)
    Dielectric strength 3000 V AC (Actuation area)
    1500 V AC (Main to auxiliary circuit)
    1500 V AC (Open main circuit)
    1000 V AC (Open auxiliary circuit)
    Switching cycles, max. 6000 (at 1 x In)
    50 (at 1.5 x In)
    40 (at 6 x In)
    Fuse M1 (normal blow)
    Power dissipation 1.1 W (in nominal operation per channel)
    Voltage drop 1.1 V (at 1 x In)
    Auxiliary contact
    Minimum operating voltage Umin DC 10 V
    Maximum operating voltage Umax DC 240 V
    Maximum operating voltage Umax. AC 240 V
    Minimum operating current Imin 10 mA
    Max. operating current Imax 1 A

    Connection method pluggable
    Connection method pluggable

    Dimensional drawing
    Width 12.3 mm
    Height 45 mm
    Depth 52 mm
    Complete module width 12.3 mm
    Complete module height 90 mm
    Complete module depth 77.3 mm

    Color gray (RAL 7042)
    black (RAL 9005)
    Flammability rating according to UL 94 V-0
    Insulating material group II

    Mechanical data
    Open side panel No

    Ambient conditions
    Degree of protection IP30 (Actuation area)
    Ambient temperature (operation) -30 °C ... 60 °C
    Ambient temperature (storage/transport) -40 °C ... 80 °C
    Humidity test 240 h, 95 % RH, 40 °C
    Shock (operation) 30g (According to IEC 60068-2-27, Test Ea)
    Vibration (operation) 8g (in accordance with IEC 60068-2-6, Test Fc)

    CB TM1 1A M1 P - Thermomagnetic device circuit breaker

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.