Home Latest Log In

PLC-OSC- 24DC、48DC 100 C1D2 - Optocoupler


  • Date:2024-05-22T02:59:33Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:31215713441188462981350115@12q10q7.1c13o14m

     Business License verifiedEmail verified

     

    PLC-OSC- 24DC/ 48DC/100/C1D2 - Optocoupler

    5603261

    PLC-INTERFACE, consisting of DIN rail-mountable basic terminal block with screw connection and plug-in miniature solid-state relay, input: 24 V DC, output: 3 - 48 V DC/100 mA, UL/cUL: approved for use in Ex Zone Class I, Div. 2


    Utilization restriction
    EMC note EMC: class A product, see manufacturer's declaration in the download area

    Product type Solid-state relay module
    Product family PLC-INTERFACE
    Application Class I, Division 2
    potentially explosive areas
    Operating mode 100% operating factor
    Insulation characteristics
    Insulation Basic insulation
    Insulation characteristics: Standards/regulations
    Insulation Basic insulation
    Overvoltage category III
    Pollution degree 2

    Maximum power dissipation for nominal condition 0.2 W
    Test voltage (Input/output) 2.5 kV (50 Hz, 1 min., input/output)

    Nominal input voltage UN 24 V DC
    () 24 V DC
    Input voltage range in reference to UN 0.8 ... 1.2
    Input voltage range 19.2 V DC ... 28.8 V DC
    Switching threshold "0" signal in reference to UN ≤ 0.4
    Switching threshold "1" signal in reference to UN ≥ 0.8
    Typical input current at UN 8.5 mA
    Typical response time 20 µs (at UN)
    Typical turn-off time 300 µs (at UN)
    Operating voltage display Yellow LED
    Protective circuit Reverse polarity protection; Polarity protection diode
    Freewheeling diode; Freewheeling diode
    Transmission frequency 300 Hz

    Contact switching type 1 N/O contact
    Design of digital output electronic
    Output voltage range 3 V DC ... 48 V DC
    Limiting continuous current 100 mA
    Voltage drop at max. limiting continuous current ≤ 1 V
    Output circuit 2-conductor, floating
    Protective circuit Reverse polarity protection; Polarity protection diode
    Surge protection

    Connection method Screw connection
    Stripping length 8 mm
    Screw thread M3
    Conductor cross section rigid 0.14 mm² ... 2.5 mm²
    Conductor cross section flexible 0.14 mm² ... 2.5 mm²
    0.2 mm² ... 2.5 mm² (Single ferrule)
    2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
    Conductor cross section AWG 26 ... 14
    Tightening torque 0.6 Nm ... 0.8 Nm

    Width 6.2 mm
    Height 80 mm
    Depth 94 mm

    Color gray (RAL 7042)
    Flammability rating according to UL 94 V0 (Housing)