GW PN/ASCII 2E/2DB9 - Interface converters
1021056
The GW PN/ASCII... converts RAW or ASCII serial strings into PROFINET. Includes two RJ45 ports and two D-SUB 9 ports.
Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction
CCCex note Use in potentially explosive areas is not permitted in China.
Product type Interface converter
MTBF 68.1 Years (Telcordia standard, 25°C temperature, 50% stress, Environmental Factor = 1.0)
45.4 Years (Telcordia standard, 40°C temperature, 50% stress, Environmental Factor = 1.5)
Electrical isolation IEC UL 61010-1 (VCC // Ethernet)
Test voltage data interface/data interface 1.5 kVrms (50 Hz, 1 min.)
Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
1.5 kVrms
Supply
Supply voltage range 10.8 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Typical current consumption 88 mA (24 V DC)
Max. current consumption 100 mA (24 V DC)
Function
Management Web-based management
Status and diagnostic indicators LEDs: Status, ACT/LNK (Ethernet data traffic)
Supply
Conductor cross section, flexible 0.20 mm² ... 2.50 mm²
Conductor cross section AWG 24 ... 12
Tightening torque 0.5 Nm ... 0.6 Nm
Signal Ethernet
PROFINET
Web server yes
Data: PROFINET
Serial transmission speed 10/100 Mbps, auto negotiation
Connection method RJ45 jack, shielded
No. of channels 2
Transmission length ≤ 100 m (shielded twisted pair)
Protocols supported PROFINET, ASCII
Auxiliary protocols ARP, DHCP (Client), PING
Data: RS-232
Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 Kbps
Number of connections 2
Connection method D-SUB 9 plug
Pin assignment DTE
Transmission length 15 m
File format/coding 5/6/7/8 Data bits, 1/2 Stop bits, None/Even/Odd/Mark/Space Parity
Data flow control/protocols Software handshake, Xon/Xoff or hardware handshake RTS/CTS
Data: RS-422
Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 Kbps
Number of connections 2
Connection method D-SUB 9 plug
Pin assignment 2, 3, 5, 7, 8
Transmission length ≤ 1200 m
Termination resistor 120 Ω (configurable)
File format/coding 5/6/7/8 Data bits, 1/2 Stop bits, None/Even/Odd/Mark/Space Parity
Data: RS-485
Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 Kbps
Number of connections 2
Connection method D-SUB 9 plug
Pin assignment 3, 5, 7
Termination resistor 120 Ω (configurable)
File format/coding 5/6/7/8 Data bits, 1/2 Stop bits, None/Even/Odd/Mark/Space Parity
![GW PN ASCII 2E 2DB9 - Interface converters](http://pic.1688club.com/1247/products/s_43929e9d5d9e5848dba995984577b344.jpg)