2799432
Fiberglass cable, duplex 50/125 µm, by the meter, without connector, for outdoor installation
Product type Data cable by the meter
Number of positions 2
Transmission medium Multi-mode fiberglass
Signal INTERBUS
PROFIBUS
Point-to-point
Ethernet
RS-485
External dimensions
External diameter min. 10 mm
External diameter max. 11 mm
Color (Outer sheath) black (RAL 9005)
Color (Single-core wire) red (RAL 3001)
Outer sheath, material PE
Cable length Free entry (1.0 ... 1000.0 m)
Cable weight 97 kg/km
Cable abbreviation AT-VQH(BN)2Y 2G50/125 2,5B600+0,7F1200
External cable diameter 10.5 mm
Outer sheath, material PE
External sheath, strain relief elements Non-metallic, aramide fiber
Outer sheath, rodent protection Glass fibers
External sheath, lengthwise water-proofing IEC 60794-1-2
Single wire, material FRNC material
Individual wire diameter 2.9 mm ±0.1 mm
Bending radius, single element 30 mm (Short-term)
30 mm (Short-term)
Bending radius, entire cable 150 mm (Short-term)
150 mm (Short-term)
Bending radius 30 mm (Short-term)
50 mm (Permanent)
150 mm (Short-term)
200 mm (Permanent)
Tensile strength short-term/long-term 1500 N / 500 N
Lateral pressure short term 500 N/cm
Lateral pressure, long-term 300 N/cm
Impact strength 1,5 Nm / 3 x
850 nm 2.5 dB/km
1300 nm 0.7 dB/km
Halogen-free According to IEC 60754-2
FO cable
Fiber Fiberglass, 50/125 µm
Tensile strength short-term/long-term 1500 N / 500 N
Ambient conditions
Impact strength 1,5 Nm / 3 x
Ambient temperature (operation) -25 °C ... 70 °C
Ambient temperature (storage/transport) -30 °C ... 70 °C
Ambient temperature (installation) -5 °C ... 50 °C
Altitude 5000 m