    Surge protection, consisting of protective plug and base element, with integrated status indicator for a 2-wire floating signal circuit with high nominal current. Can be used in safety-related circuits up to SIL 3.

    Product type Surge protection for MCR technology
    Product family TERMITRAB complete
    IEC test classification C1
    C2
    C3
    D1
    Type DIN rail module, two-section, divisible
    Insulation characteristics
    Overvoltage category III
    Pollution degree 2

    Nominal voltage UN 24 V DC

    Connection method Screw connection
    Screw thread M3
    Tightening torque 0.5 Nm ... 0.6 Nm
    Conductor cross section flexible 0.2 mm² ... 2.5 mm²
    Conductor cross section rigid 0.2 mm² ... 4 mm²
    Conductor cross section AWG 24 ... 12

    Dimensional drawing
    Width 6.2 mm +0.1 mm
    Height 105.8 mm
    Depth 100 mm (incl. DIN rail 7.5 mm)

    Color (Base element) gray (RAL 7042)
    Color (Male connector) light grey (RAL 7035)
    Flammability rating according to UL 94 V-0
    Insulating material PBT
    Housing material PBT

    Mechanical data
    Open side panel No

    Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
    Maximum continuous voltage UC 30 V DC
    21 V AC
    Rated current 6 A (55 °C)
    Operating effective current IC at UC ≤ 5 µA
    Residual current IPE ≤ 1 µA
    Nominal discharge current In (8/20) µs (line-line) 0.5 kA
    Nominal discharge current In (8/20) µs (line-ground) 5 kA
    Pulse discharge current Iimp (10/350) µs (line-earth) 0.5 kA
    Total discharge current Itotal (8/20) µs 5 kA
    Voltage protection level Up (line-line) ≤ 50 V (C1 - 1 kV / 500 A)
    ≤ 45 V (C3 - 25 A)
    ≤ 50 V (C3 - 100 A)
    Voltage protection level Up (line-earth) ≤ 1.35 kV (C1 - 1 kV / 500 A)
    ≤ 1.45 kV (C2 - 10 kV / 5 kA)
    ≤ 850 V (C3 - 25 A)
    ≤ 1.1 kV (C3 - 100 A)
    Response time tA (line-line) ≤ 1 ns
    Response time tA (line-earth) ≤ 100 ns
    Input attenuation aE, sym. typ. 0.3 dB (≤ 300 kHz / 150 Ω)
    Cut-off frequency fg (3 dB), sym. in 150 Ω system typ. 1 MHz
    Capacity (Core-Earth) typ. 2.2 nF
    Resistance per path ≤ 100 mΩ
    Surge protection fault message optical
    Max. required back-up fuse 6.3 A (FF)
    Impulse durability (line-line) C1 - 1 kV / 500 A
    C3 - 100 A
    Impulse durability (line-earth) C1 - 1 kV / 500 A
    C2 - 10 kV / 5 kA