TMC 1 F1 100 2,0A - Thermomagnetic device circuit breaker
0914099
Thermomagnetic device circuit breaker, number of positions: 1, connection method: Screw connection, cross section: 0.2 mm2- 6 mm2, AWG: 24 - 10, nominal current: 2 A, fuse type: Automatic device, mounting type: DIN rail: 35 mm
Product type Thermomagnetic device circuit breakers
Product family TMC
Type DIN rail module, one-piece
Number of positions 1
Number of connections 4
Number of rows 2
No. of channels 1
Insulation characteristics
Overvoltage category II
Degree of pollution 2
Fuse type Automatic device
General
Rated voltage 65 V DC
Rated current IN 2 A
Rated surge voltage 2.5 kV
Insulation resistance Riso > 100 MΩ (500 V DC)
Auxiliary circuit 240 V AC / 1 A (Low-induction)
65 V AC / 1 A (Low-induction)
Tripping method TM (thermomagnetic)
Device resistance 0.42 Ω
Rated short-circuit switching capacity Icn 2500 A (32 V DC)
Short-circuit switching capacity 2000 A (UL 1077: 65 V DC)
Dielectric strength 3000 V AC (Actuation area)
3000 V AC (Main to auxiliary circuit)
Switching cycles, max. 10000 (At 1 x In, inductive)
Fuse F1 (fast blow)
Indicator/remote signaling
Connection name Auxiliary contact
Operating voltage 250 V AC
65 V DC
Operating current 2 A AC (Low-induction)
Main contact
Screw thread M3
Tightening torque 0.6 ... 0.8 Nm
Stripping length 12 mm
Internal cylindrical gage A3
Conductor cross section rigid 0.2 mm² ... 6 mm²
Cross section AWG 24 ... 10 (converted acc. to IEC)
Conductor cross section flexible 0.2 mm² ... 4 mm²
Conductor cross-section flexible (ferrule without plastic sleeve) 0.25 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.25 mm² ... 2.5 mm²
2 conductors with same cross section, solid 0.2 mm² ... 0.75 mm²
2 conductors with same cross section, flexible 0.2 mm² ... 0.75 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.25 mm² ... 1 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 2.5 mm²
Nominal current 2 A
Auxiliary contact
Screw thread M3
Tightening torque 0.6 ... 0.8 Nm
Stripping length 12 mm
Internal cylindrical gage A1
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Cross section AWG 24 ... 14 (converted acc. to IEC)
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross-section flexible (ferrule without plastic sleeve) 0.25 mm² ... 2.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.25 mm² ... 1.5 mm²
2 conductors with same cross section, solid 0.2 m² ... 0.75 m²
2 conductors with same cross section, flexible 0.2 m² ... 0.75 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.25 mm² ... 0.5 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 0.75 mm²
Main contact
Connection method Screw connection
Screw thread M3
Tightening torque 0.6 Nm ... 0.8 Nm
Stripping length 12 mm
Conductor cross section flexible 0.2 mm² ... 4 mm²
Conductor cross section rigid 0.2 mm² ... 6 mm²
Conductor cross section AWG 24 ... 10
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 2.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 4 mm²
Auxiliary contact
Connection method Screw connection
Screw thread M3
Tightening torque 0.6 Nm ... 0.8 Nm
Stripping length 12 mm
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross section rigid 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
Conductor cross section, flexible, with ferrule, with plastic sleeve 0.25 mm² ... 1.5 mm²
Conductor cross section flexible, with ferrule without plastic sleeve 0.25 mm² ... 2.5 mm²
![TMC 1 F1 100 2,0A - Thermomagnetic device circuit breaker](http://pic.1688club.com/1247/products/s_525b5686022f44d9496a126d8f881ef4.jpg)