FL IF 2FX ST-D - Media module
2884033
Fiber optic interface module for connecting 100 Base-FX multi-mode glass fibers (1300 nm), ST, connection direction downward
For customers who wish to use this Interface module in the FL SWITCH MM HS (Item No. 2832328), please refer to the document entitled “Customer information for IF modules” in the download area for this Interface module.
Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Product type Extension module
Type fine granularity
Functionality
Basic functions Media module for modular managed switch
Electrical isolation 100Base-FX // supply
Maximum power dissipation for nominal condition 21.6 W
Test voltage 2 kV AC
Transmission medium Copper
FO
Supply
Supply voltage via head station
Power supply connection From FL SWITCH GHS or FXT
Typical current consumption 200 mA
Ethernet: 100Base-FX in acc. with IEEE 802.3
Transmission length 10000 m (maximum (depends on the fiber used))
Ethernet: 100Base-FX in acc. with IEEE 802.3
Connection method ST
Transmission speed 100 Mbps
Transmission length 10000 m (fiberglass with F-G 62.5/125 0.7 dB/km F1000)
6400 m (fiberglass with F-G 50/125 0.7 dB/km F1200)
3000 m (fiberglass with F-G 62.5/125 2.6 dB/km F600)
2800 m (fiberglass with F-G 50/125 1.6 dB/km F800)
Wavelength 1300 nm
No. of channels 2 (ST multi-mode)
Width 31 mm
Height 83 mm
Depth 72.5 mm
Color green
Flammability rating according to UL 94 V0
Housing material PA
Ambient conditions
Degree of protection IP20
Ambient temperature (operation) 0 °C ... 55 °C (non-condensing)
Ambient temperature (storage/transport) -20 °C ... 70 °C
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 10 % ... 95 % (non-condensing)
Vibration (operation) in acc. with IEC 60068-2-6: 5g, 150 Hz
Conformance with EMC directives IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion B
IEC 61000-4-3 (immunity to radiated interference) Criterion A
IEC 61000-4-4 (burst) Criterion A
IEC 61000-4-5 (surge) Criterion A
IEC 61000-4-6 (immunity to conducted interference) Criterion A
IEC 61000-4-8 (immunity to magnetic fields) Criterion A
EN 55022 (emitted interference) Criterion A
Noise immunity EN 61000-6-2:2005
Electromagnetic compatibility Conformance with EMC Directive 2004/108/EC
Noise emission EN 61000-6-3/-4
Free from substances that could impair the application of coating In acc. with VW specification
Electrical isolation 100Base-FX // supply
Mounting type In the host system
![FL IF 2FX ST-D - Media module](http://pic.1688club.com/1247/products/s_39b5499d75fff757864ca1c86e55448b.jpg)