Home Latest Log In

PLC-OPT- 12DC 300DC 1 - Solid-state relay module


  • Date:2024-05-21T06:16:36Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:4136541484851149613851015@50qq97.c11o10m

     Business License verifiedEmail verified

     

    PLC-OPT- 12DC/300DC/1 - Solid-state relay module

    2900382

    PLC-INTERFACE, integrated solid-state relay, with push-in connection, for mounting on NS 35/7,5 DIN rails, input: 12 V DC, output: 12 - 300 V DC/1 A

    Product type Solid-state relay module
    Product family PLC-INTERFACE
    Application With integrated solid-state relay
    Operating mode 100% operating factor
    Insulation characteristics
    Insulation Basic insulation
    Insulation characteristics: Standards/regulations
    Insulation Basic insulation
    Overvoltage category III
    Pollution degree 2

    Maximum power dissipation for nominal condition 0.07 W
    Standards/regulations
    Rated insulation voltage 300 V
    Rated surge voltage 2.5 kV

    Nominal input voltage UN 12 V DC
    Input voltage range in reference to UN 0.8 ... 1.2
    Input voltage range 9.6 V DC ... 14.4 V DC
    Switching threshold "0" signal in reference to UN ≤ 0.4
    Switching threshold "1" signal in reference to UN ≥ 0.8
    Typical input current at UN 6 mA
    Typical response time 0.3 ms
    Typical turn-off time 0.8 ms
    Operating voltage display Yellow LED
    Protective circuit Reverse polarity protection; Polarity protection diode
    Surge protection; Varistor
    Transmission frequency 50 Hz

    Designation Output data
    Contact switching type 1 N/O contact
    Design of digital output electronic
    Output voltage range 12 V DC ... 300 V DC (Partition plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal points in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...)
    Limiting continuous current 1 A (see derating curve)
    Voltage drop at max. limiting continuous current < 500 mV
    Protective circuit Reverse polarity protection; Polarity protection diode
    Surge protection; Varistor

    Connection method Push-in connection
    Stripping length 10 mm
    Conductor cross section rigid 0.14 mm² ... 2.5 mm²
    Conductor cross section flexible 0.14 mm² ... 2.5 mm²
    0.2 mm² ... 2.5 mm² (Single ferrule)
    2x 0.5 mm² ... 1 mm² (TWIN ferrule)
    Conductor cross section AWG 26 ... 14

    Width 6.2 mm
    Height 80 mm
    Depth 95 mm

    Color gray (RAL 7042)
    Flammability rating according to UL 94 V0 (Housing)

    Ambient conditions
    Ambient temperature (operation) -25 °C ... 60 °C
    Ambient temperature (storage/transport) -40 °C ... 85 °C

    CE
    Certificate CE-compliant
    UKCA
    Certificate UKCA-compliant
    Shipbuilding approval
    Certificate TAE0000196
    Corrosive gas test
    Identification ISA-S71.04. G3 Harsh Group
    EN 60068-2-60