    CB TM2 4A SFB P - Thermomagnetic device circuit breaker

    2800872

    Thermomagnetic device circuit breaker, 2-pos., tripping characteristic SFB, 2 changeover contacts, plug for base element.

    Thermomagnetic device circuit breaker

    General When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.

    Product type Thermomagnetic device circuit breakers
    Product family CB TM
    Type Male
    Number of positions 2
    No. of channels 1
    Insulation characteristics
    Degree of pollution 2

    Fuse type Automatic device
    General
    Rated voltage 80 V DC (IEC 60934)
    80 V DC (UL 1077)
    80 V DC (UL 508 - with plug-in base)
    Rated insulation voltage Ui 277 V AC (UL 1077)
    250 V AC (IEC 60934)
    Rated current IN 4 A (IEC 60934)
    inductive load according to UL 1077
    4 A DC (low-induction load according to UL 1077)
    4 A DC (inductive load according to UL 508 - with plug-in base)
    4 A DC (low-induction load according to UL 508 - with plug-in base)
    Rated surge voltage 2.5 kV (Increased insulation in actuation area)
    Insulation resistance Riso > 100 MΩ (500 V DC)
    Auxiliary circuit 277 V AC / 0.5 A (Low-induction)
    277 V AC / 1 A (Low-induction, maximum of 2000 cycles)
    50 V DC / 1 A (Low-induction)
    Type of actuation S type
    Tripping method TM (thermomagnetic)
    Tripping level Trip-free mechanism (positive)
    Device resistance 90 mΩ
    Required backup fuse ≥ 16 A (I > Icn)
    Rated short-circuit switching capacity Icn 600 A (80 V DC)
    Short-circuit switching capacity 1000 A AC (277 V AC)
    1000 A DC (50 V DC)
    Dielectric strength 3000 V AC (Actuation area)
    1500 V AC (Main to auxiliary circuit)
    1500 V AC (Open main circuit)
    1000 V AC (Open auxiliary circuit)
    1500 V AC (Position to position)
    Switching cycles, max. 6000 (240 V AC / 1 x In)
    3000 (80 V DC/1 x In)
    Fuse SFB
    Power dissipation 1.44 W (in nominal operation per channel)
    Voltage drop 0.34 V (at 1 x In)
    Auxiliary contact
    Minimum operating voltage Umin DC 10 V
    Maximum operating voltage Umax DC 240 V
    Maximum operating voltage Umax. AC 240 V
    Minimum operating current Imin 10 mA
    Max. operating current Imax 1 A

    Connection method pluggable
    Connection method pluggable

    Dimensional drawing
    Width 24.6 mm
    Height 45 mm
    Depth 52 mm

    Color gray (RAL 7042)
    black (RAL 9005)
    Flammability rating according to UL 94 V-0
    Insulating material group II

    Mechanical data
    Open side panel No

    Ambient conditions
    Degree of protection IP30 (Actuation area)
    Ambient temperature (operation) -30 °C ... 60 °C
    Ambient temperature (storage/transport) -40 °C ... 80 °C
    Humidity test 240 h, 95 % RH, 40 °C
    Shock (operation) 30g (IEC 60068-2-27, Test Ea)
    Vibration (operation) 8g (IEC 60068-2-6, Test Fc)