    Thermomagnetic device circuit breaker, 1-pos., tripping characteristic M1 (medium-blow), 1 changeover contact, plug for base element.


    General When mounted in rows, the nominal device current can be limited to just 80% or must be overdimensioned accordingly.

    Product type Thermomagnetic device circuit breakers
    Product family CB TM
    Type Male
    Number of positions 1
    No. of channels 1
    Insulation characteristics
    Degree of pollution 2

    Fuse type Automatic device
    General
    Rated voltage 50 V DC (IEC 60934)
    50 V DC (UL 1077)
    50 V DC (UL 508 - with plug-in base)
    240 V AC (Ue according to IEC 60934)
    277 V AC (UL 1077)
    277 V AC (UL 508 - with plug-in base)
    Rated insulation voltage Ui 277 V AC (UL 1077)
    250 V AC (IEC 60934)
    Rated current IN 8 A (IEC 60934)
    8 A AC (inductive load according to UL 1077)
    8 A DC (low-induction load according to UL 1077)
    8 A AC (inductive load according to UL 508 - with plug-in base)
    8 A DC (low-induction load according to UL 508 - with plug-in base)
    Rated surge voltage 2.5 kV (Increased insulation in actuation area)
    Insulation resistance Riso > 100 MΩ (500 V DC)
    Auxiliary circuit 277 V AC / 0.5 A (Low-induction)
    277 V AC / 1 A (Low-induction, maximum of 2000 cycles)
    50 V DC / 1 A (Low-induction)
    Type of actuation S type
    Tripping method TM (thermomagnetic)
    Tripping level Trip-free mechanism (positive)
    Device resistance 18 mΩ
    Required backup fuse 32 A (I > Icn)
    Rated short-circuit switching capacity Icn 300 A (240 V AC)
    600 A (50 V DC)
    Short-circuit switching capacity 1000 A AC (277 V AC)
    1000 A DC (50 V DC)
    Dielectric strength 3000 V AC (Actuation area)
    1500 V AC (Main to auxiliary circuit)
    1500 V AC (Open main circuit)
    1000 V AC (Open auxiliary circuit)
    Switching cycles, max. 6000 (at 1 x In)
    Fuse M1 (normal blow)
    Power dissipation 1.28 W (in nominal operation per channel)
    Voltage drop 0.14 V (at 1 x In)
    Auxiliary contact
    Minimum operating voltage Umin DC 10 V
    Maximum operating voltage Umax DC 240 V
    Maximum operating voltage Umax. AC 240 V
    Minimum operating current Imin 10 mA
    Max. operating current Imax 1 A

    Connection method pluggable