Home Latest Log In

PLC-RSC- 24DC、1ICT ACT - Relay Module


  • Date:2024-05-21T06:03:16Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:6143548848504911485135105@q313q.810co4m

     Business License verifiedEmail verified

     

    PLC-RSC- 24DC/ 1ICT/ACT - Relay Module

    1078680

    PLC-INTERFACE for high inrush currents, consisting of PLC-BSC.../1 IC/ACT basic terminal block with screw connection and pluggable miniature relay, for mounting on DIN rail NS 35/7.5, max. inrush current up to 800 A, 1 N/O contact, 24 V DC input voltage

    The relay module is particularly suitable for switching strong capacitive loads, such as LED lights. The ballasts installed in the LED lights often have extremely high switch-on peaks which cause standard relay contacts to fuse. The leading tungsten pre-contact ensures that switch-on currents of up to 800 A can be switched safely.

    Notes on operation Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500....
    Notes on operation The PLC-ATP separating plate should be installed for safe isolation between adjacent modules
    Assembly note The PLC-ATP separating plate is required at the start and end of every PLC terminal strip.
    Notes on operation The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.

    Product type Relay Module
    Product family PLC-INTERFACE
    Application high inrush currents
    Operating mode 100% operating factor
    Mechanical service life 3x 107 cycles
    Insulation characteristics
    Insulation Safe isolation, reinforced insulation
    Insulation characteristics: Standards/regulations
    Insulation Safe isolation, reinforced insulation
    Overvoltage category III
    Pollution degree 3

    Maximum power dissipation for nominal condition 0.43 W
    Test voltage (Winding/contact) 4 kV AC (50 Hz, 1 min., winding/contact)
    Standards/regulations
    Rated insulation voltage 250 V AC
    Rated surge voltage 6 kV

    Coil side
    Nominal input voltage UN 24 V DC
    Input voltage range 20.2 V DC ... 33.6 V DC (20 °C)
    () 24 V DC
    Drive and function monostable
    Drive (polarity) polarized
    Typical input current at UN 18 mA
    Typical response time 8 ms
    Typical release time 10 ms
    Coil voltage 24 V DC
    Protective circuit Reverse polarity protection; Polarity protection diode
    Freewheeling diode; Freewheeling diode
    Operating voltage display Yellow LED

    Switching
    Contact switching type 1 N/O contact
    Type of switch contact Single contact
    Note regarding the switch contact With tungsten leading contact
    Contact material AgSnO
    Note Main contact silver tin oxide (AgSnO2): lead contact tungsten
    Maximum switching voltage 250 V AC/DC
    Minimum switching voltage 12 V (100 mA)
    Limiting continuous current 6 A
    10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged)
    Maximum inrush current 165 A (20 ms)
    800 A (200 µs)
    Min. switching current 100 mA (12 V)
    Interrupting rating (ohmic load) max. 144 W (at 24 V DC)
    58 W (at 48 V DC)
    48 W (at 60 V DC)
    50 W (at 110 V DC)
    80 W (at 220 V DC)
    1500 VA (for 250 V AC)
    Interrupting rating (ohmic load) max. bridged 240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.)
    2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.)
    Switching capacity min. 1200 mW
    Switching capacity 2 A (at 24 V, DC13)
    0.2 A (at 110 V, DC13)
    0.2 A (at 250 V, DC13)
    6 A (at 24 V, AC15)
    6 A (at 120 V, AC15)
    6 A (at 250 V, AC15)

    Connection method Screw connection
    Stripping length 8 mm
    Screw thread M3
    Conductor cross section rigid 0.14 mm² ... 2.5 mm²
    Conductor cross section flexible 0.14 mm² ... 2.5 mm²
    0.2 mm² ... 2.5 mm² (Single ferrule)
    2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
    Conductor cross section AWG 26 ... 14
    Tightening torque 0.6 Nm ... 0.8 Nm

    PLC-RSC- 24DC、1ICT ACT - Relay Module

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

Top

PC | Touch