TTC-6-2X1-F-M-24DC-PT-I - Surge protection device


  • Date:2024-05-21T05:48:59Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:310512114488846978225510@41qq06.c10o12m

     Business License verifiedEmail verified

     

    TTC-6-2X1-F-M-24DC-PT-I - Surge protection device

    2906776

    Surge protection with integrated status indicator and disconnect knife for two signal wires with common reference potential. Indirect grounding via gas discharge tube, e.g., Digital IN/OUT. Can be used in safety-related circuits up to SIL 3.

    Product type Surge protection for MCR technology
    Product family TERMITRAB complete
    IEC test classification C1
    C2
    C3
    D1
    Type DIN rail module, one-piece
    Insulation characteristics
    Overvoltage category III
    Pollution degree 2

    Nominal voltage UN 24 V DC

    Connection method Push-in connection
    Conductor cross section flexible 0.2 mm² ... 2.5 mm²
    Conductor cross section rigid 0.2 mm² ... 4 mm²
    Conductor cross section AWG 24 ... 12

    Dimensional drawing
    Width 6.2 mm +0.1 mm
    Height 105.8 mm
    Depth 83.5 mm (incl. DIN rail 7.5 mm)

    Color gray (RAL 7042)
    light grey (RAL 7035)
    Flammability rating according to UL 94 V-0
    Insulating material PBT
    Housing material PBT

    Mechanical data
    Open side panel No

    Direction of action Line-Line & Line-Signal Ground/Shield & optional Signal Ground/Shield-Earth Ground
    Maximum continuous voltage UC 30 V DC
    21 V AC
    Rated current 600 mA (40 °C)
    Operating effective current IC at UC ≤ 5 µA
    Residual current IPE ≤ 1 µA
    Nominal discharge current In (8/20) µs (line-ground) 5 kA
    Nominal discharge current In (8/20) µs (line-signal ground) 5 kA
    Pulse discharge current Iimp (10/350) µs (line-earth) 0.5 kA
    Pulse discharge current Iimp (10/350) µs (line-signalground) 0.5 kA
    Total discharge current Itotal (8/20) µs 10 kA
    Voltage protection level Up (line-earth) ≤ 750 V (C1 - 1 kV / 500 A)
    ≤ 750 V (C2 - 10 kV / 5 kA)
    ≤ 1.1 kV (C3 - 25 A)
    ≤ 1.15 kV (C3 - 100 A)
    Voltage protection level Up (line-signalground) ≤ 140 V (C1 - 1 kV / 500 A)
    ≤ 130 V (C2 - 10 kV / 5 kA)
    ≤ 45 V (C3 - 25 A)
    ≤ 50 V (C3 - 100 A)
    Voltage protection level Up static (line-earth) ≤ 750 V (C1 - 1 kV / 500 A)
    ≤ 750 V (C2 - 10 kV / 5 kA)
    Voltage protection level Up static (line-signalground) ≤ 55 V (C1 - 1 kV / 500 A)
    ≤ 80 V (C2 - 10 kV / 5 kA)
    Response time tA (line-earth) ≤ 100 ns
    Response time tA (line-signalground) ≤ 1 ns
    Input attenuation aE, asym. typ. 0.3 dB (≤ 270 kHz/150 Ω)
    Cut-off frequency fg (3 dB), asym. (signal ground) in 150 Ω system typ. 960 kHz
    Capacity (line-signalground) typ. 2.2 nF
    Resistance per path 1.65 Ω ±20 %
    Surge protection fault message optical
    Max. required back-up fuse 630 mA (FF)
    Impulse durability (line-earth) C1 - 1 kV / 500 A
    C2 - 10 kV / 5 kA
    C3 - 100 A
    D1 - 500 A
    Impulse durability (line-signalground) C1 - 1 kV / 500 A
    C2 - 10 kV / 5 kA
    C3 - 100 A
    D1 - 500 A
    Pulse reset time (line-earth) ≤ 30 ms
    Pulse reset time (line-signalground) ≤ 300 ms
    Additional technical data
    Max. total discharge current I total max (8/20) µs 20 kA (1x)

    Ambient conditions
    Degree of protection IP20
    Ambient temperature (operation) -40 °C ... 85 °C
    Ambient temperature (storage/transport) -40 °C ... 85 °C
    Altitude ≤ 4000 m (amsl)
    Permissible humidity (operation) 5 % ... 95 %