Home Latest Log In

PLC-OPT- 24DC、48DC 500 W - Solid-state relay module


  • Date:2024-05-21T05:48:03Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:5135994481384119981455512@10qq0.1012co2m

     Business License verifiedEmail verified

     

    PLC-OPT- 24DC/ 48DC/500/W - Solid-state relay module

    2900378

    PLC-INTERFACE with electronic changeover contact, consisting of PLC-BPT…/21 basic terminal block with Push-in connection and integrated miniature solid-state relay, for mounting on DIN rail NS 35/7,5, 1 changeover contact, input: 24 V DC, output: 3-48 V DC/500 mA

    Product type Solid-state relay module
    Product family PLC-INTERFACE
    Application With integrated solid-state relay
    Operating mode 100% operating factor
    Insulation characteristics
    Insulation Basic insulation
    Insulation characteristics: Standards/regulations
    Insulation Basic insulation
    Overvoltage category III
    Pollution degree 2

    Maximum power dissipation for nominal condition 0.07 W
    Standards/regulations
    Rated insulation voltage 300 V
    Rated surge voltage 4 kV

    Nominal input voltage UN 24 V DC
    Input voltage range in reference to UN 0.8 ... 1.2
    Input voltage range 19.2 V DC ... 28.8 V DC
    Switching threshold "0" signal in reference to UN ≤ 0.4
    Switching threshold "1" signal in reference to UN ≥ 0.8
    Typical input current at UN 3 mA
    Typical response time 0.03 ms
    Typical turn-off time 0.15 ms
    Operating voltage display Yellow LED
    Protective circuit Reverse polarity protection; Polarity protection diode
    Surge protection
    Transmission frequency 1000 Hz

    Contact switching type 1 changeover contact
    Design of digital output electronic
    Contact connection type Power contact
    Output voltage range 3 V DC ... 48 V DC
    Limiting continuous current 500 mA (see derating curve)
    Min. load current 1 mA
    Voltage drop at max. limiting continuous current < 1.2 V
    Output circuit 2-conductor, floating
    Protective circuit Reverse polarity protection; Polarity protection diode
    Surge protection

    Connection method Push-in connection
    Stripping length 10 mm
    Conductor cross section rigid 0.14 mm² ... 2.5 mm²
    Conductor cross section flexible 0.14 mm² ... 2.5 mm²
    0.2 mm² ... 2.5 mm² (Single ferrule)
    2x 0.5 mm² ... 1 mm² (TWIN ferrule)
    Conductor cross section AWG 26 ... 14

    Width 6.2 mm
    Height 80 mm
    Depth 95 mm

    Color gray (RAL 7042)
    Flammability rating according to UL 94 V0 (Housing)

    Ambient conditions
    Ambient temperature (operation) -25 °C ... 60 °C
    Ambient temperature (storage/transport) -40 °C ... 85 °C

    Corrosive gas test
    Identification ISA-S71.04. G3 Harsh Group
    EN 60068-2-60

    Standards/regulations
    Standards/regulations IEC 60664
    EN 50178

    PLC-OPT- 24DC、48DC 500 W - Solid-state relay module