Home Latest Log In

ELR W3- 24DC 500AC- 2 - Solid-state reversing contactor


  • Date:2024-05-21T05:41:45Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:191513410104814294885425@97qq131.c40om

     Business License verifiedEmail verified

     

    ELR W3- 24DC/500AC- 2 - Solid-state reversing contactor

    2297293

    Three-phase solid-state reversing contactor with 24 V DC input, 2 A output current, zero voltage switch, optionally with thermal fuse

    Product type Solid-state contactor
    Operating mode 100% operating factor

    Number of phases 3
    Test voltage (Input/output) 5 kVrms (50 Hz, 60 s)
    Switching frequency max. 5 Hz
    Reversing frequency ≤ 10 Hz
    Insulation characteristics
    Rated insulation voltage 500 V
    Rated surge voltage 6 kV
    Overvoltage category III
    Degree of pollution 2
    Insulation characteristics between the control input voltage to the main circuit Basic insulation

    Control
    Input name Control input right/left
    Rated actuating voltage UC 24 V DC
    Triggering voltage range 19.2 V DC ... 30 V DC
    Voltage range with reference to UC 0.8 ... 1.25
    0.8 ... 1.25
    Rated actuating current IC 12.7 mA
    Switching threshold 9.6 V (“0” signal)
    19.2 V (“1” signal)
    Protective circuit Reverse polarity protection; Suppressor diode
    Surge protection
    Error indication Red LED
    Status display Yellow LED

    AC output
    Rated operating voltage Ue 500 V AC
    Operating voltage range 48 V AC ... 575 V AC
    Rated operating current at AC-51 2 A
    Rated operating current at AC-53a 2 A
    Peak offstate voltage 1200 V
    Mains frequency 40 Hz ... 100 Hz
    Load current range 100 mA ... 2 A (see to derating)
    Leakage current 6 mA
    Residual voltage < 1.5 V
    Surge current 200 A (t = 10 ms)
    Max. load value 250 A2s
    Protective circuit RCV circuit
    Surge voltage protection > 575 V AC

    Control circuits
    Connection method Screw connection
    Stripping length 8 mm
    Screw thread M3
    Conductor cross section rigid 0.2 mm² ... 2.5 mm²
    Conductor cross section flexible 0.2 mm² ... 2.5 mm²
    Conductor cross section AWG 24 ... 14
    Tightening torque 0.5 Nm ... 0.6 Nm
    5 lbf-in. ... 7 lbf-in.
    Load circuit
    Connection method Screw connection
    Stripping length 8 mm
    Screw thread M3
    Conductor cross section rigid 0.2 mm² ... 2.5 mm²
    Conductor cross section flexible 0.2 mm² ... 2.5 mm²
    Conductor cross section AWG 24 ... 14
    Tightening torque 0.5 Nm ... 0.6 Nm
    5 lbf-in. ... 7 lbf-in.

    Status display Yellow LED
    Error indication Red LED

    Width 40 mm
    Height 99 mm
    Depth 114.5 mm

    Ambient conditions
    Degree of protection IP20
    Ambient temperature (operation) -25 °C ... 70 °C
    Ambient temperature (storage/transport) -25 °C ... 70 °C

    ELR W3- 24DC 500AC- 2 - Solid-state reversing contactor