Home Latest Log In

PLT-SEC-T3-60-FM-PT - Type 3 surge protection device


  • Date:2024-05-20T06:52:21Z
    Price:Negotiation
    Company:上海当临自动化科技有限公司
    Place:China - Shanghai
    Address:上海市青浦区练西公路2850号1幢
    Contact:Jason(Manager)
    Contact Me:
    Tell:+86-19921425125
     Mobile:+86-19921425125
     Email:61565444838411918652125@13q11q1.00co13m

     Business License verifiedEmail verified

     

    PLT-SEC-T3-60-FM-PT - Type 3 surge protection device

    2907926

    Type 3 surge protection, consisting of protective plug and base element, with integrated status indicator and remote signaling for single-phase power supply networks. Nominal voltage: 60 V AC/DC


    Product type Device protection
    Product family SEC Family
    IEC power supply system TN-S
    Type DIN rail module, two-section, divisible
    Number of positions 2
    Surge protection fault message Optical, remote indicator contact
    Insulation characteristics
    Overvoltage category III
    Pollution degree 2
    IEC test classification III
    T3
    EN type T3
    Number of ports One

    Indicator/remote signaling
    Connection name Remote fault indicator contact
    Switching function Changeover contact
    Operating voltage 250 V AC
    125 V DC (200 mA DC)
    Operating current 0.5 A AC
    0.5 A DC (75 V DC)

    Connection method Push-in connection
    Conductor cross section flexible 0.2 mm² ... 2.5 mm²
    Conductor cross section rigid 0.2 mm² ... 4 mm²
    Conductor cross section AWG 24 ... 12

    Dimensional drawing
    Width 17.7 mm
    Height 101 mm
    Depth 74.5 mm (incl. DIN rail 7.5 mm)
    Horizontal pitch 1 Div.

    Color (Male connector) light grey (RAL 7035)
    Color (Base element) gray (RAL 7042)
    Flammability rating according to UL 94 V-0
    CTI value of material 600
    Insulating material PA 6.6-FR 20 % GF
    PA 6.6-FR
    Housing material PA 6.6-FR 20 % GF
    PA 6.6-FR

    Mode of protection L-N
    L-PE
    N-PE
    Direction of action 1L-N & N-PE
    Nominal voltage UN 60 V AC (TN-S)
    Nominal frequency fN 50 Hz (60 Hz)
    Maximum continuous voltage UC 80 V AC
    Rated load current IL 26 A (at 30 °C)
    Residual current IPE ≤ 5 µA
    Standby power consumption PC ≤ 5.30 mVA (at UREF)
    ≤ 8.40 mVA (at UC)
    Reference test voltage UREF 66.00 V AC
    Nominal discharge current In (8/20) µs 2 kA
    Combination wave UOC 4 kV
    Voltage protection level Up (L-N) ≤ 0.48 kV
    Voltage protection level Up (L-PE) ≤ 0.8 kV
    Voltage protection level Up (N-PE) ≤ 0.8 kV
    TOV behavior at UT (L-N) 120 V AC (120 min / withstand mode)
    TOV behavior at UT (L-PE) 120 V AC (120 min / withstand mode)
    Response time tA (L-N) ≤ 25 ns
    Response time tA (L-PE) ≤ 100 ns
    Response time tA (N-PE) ≤ 100 ns
    Short-circuit current rating ISCCR 10 kA AC
    Max. backup fuse with branch wiring 32 A (gG / B / C)
    Additional technical data
    Short-circuit current rating ISCCR 0.25 kA DC (Without additional backup fuse in the DC branch wiring)
    5 kA DC (for 20 A gG / B backup fuse)
    Maximum discharge current Imax (8/20) µs 4 kA
    Residual voltage Ures (L-N) ≤ 0.42 kV (at 1 kA)
    ≤ 0.48 kV (at 2 kA)
    ≤ 0.4 kV (at UOC = 2 kV)
    Residual voltage Ures (L-PE) ≤ 0.55 kV (at 1 kA)
    ≤ 0.6 kV (at 2 kA)
    ≤ 0.6 kV (at UOC = 2 kV)
    Residual voltage Ures (N-PE) ≤ 0.55 kV (at 1 kA)
    ≤ 0.6 kV (at 2 kA)
    ≤ 0.6 kV (at UOC = 2 kV)
    Maximum continuous voltage UC 80 V DC
    Mode of protection (DC+) - (DC-)
    (DC+/DC-) - PE

    PLT-SEC-T3-60-FM-PT - Type 3 surge protection device

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

Top

PC | Touch